Description

The main scenario for organizing the connection with mobile objects is the following (see Figure 1):

  • The base stations BS1, BS2 and BS3 are installed along the area perimeter, forming the backhaul radio network. Single-sector base station configurations are used, i.e. each BS has one sector. Non-overlapping frequency channels are configured on the base station sectors.
  • A mobile object moves within the backhaul radio network from point A to point B. A subscriber terminal, CPE1, is installed on the mobile object. Depending on the requirements for the connection reliability, there are two implementation options: the installation of one subscriber with an antenna having a circular radiation pattern, or the installation of two subscribers on each moving object. During the motion, CPE1 can establish a radio link with the devices of the backhaul radio network - BS1, BS2 and BS3.
  • The aggregation node is located near BS2, where the InfiMUX is installed. All BSs sectors are connected to the InfiMUX, which joins the radio backhaul network devices into a single MINT area.
  • The aggregation node and the enterprise LAN are connected via the Master-Slave backbone link.
  • The Global function is enabled on CPE1 and on the InfiMUX.
  • "Mode nomadic" is set on the backhaul radio network devices and on CPE1, "mode fixed" - on the Master and Slave devices. Depending on the project specifics, other mode values may be set.
  • For device management, VLAN 100 is reserved, which is associated with the 192.168.100.0/24 subnet.
  • VLAN 200 is used for the data transmission service.

Figure 1 - Example of a project with mobile objects

Planning

Radio and data settings are in table below:

Table 1 - Radio settings for a project with mobile objects
Device nameCenter frequencyChannel widthRole
Master500020master
Slave500020slave
BS1510020master
BS2520020master
BS3530020master


CPE1

510020slave
520020slave
530020slave
Table 2 - data transfer settings for project with mobile objects
Device nameSVI interface IP addressVLANSwitch groupsGlobalMode
Master192.168.100.201/24100,200100,200nofixed
Slave192.168.100.202/24100,200100,200nofixed
InfiMUX192.168.100.200/24100,200100,200yesnomadic
BS1192.168.100.1/24100,200100nonomadic
BS2192.168.100.2/24100,200100nonomadic
BS3192.168.100.3/24100,200100nonomadic
CPE1192.168.100.101/24100,200100,200yesnomadic

Configuration

Devices configuration via CLI:

  • configure the radio parameters:

    Master device radio configuration example
    #Radio module parameters
     rf rf5.0 band 20
     rf rf5.0 mimo
     rf rf5.0 freq 5000 bitr auto sid 10101010 burst
     rf rf5.0 txpwr max pwrctl distance auto
    
    #MINT configuration
     mint rf5.0 -name "Master"
     mint rf5.0 -type master
     mint rf5.0 -mode fixed
     mint rf5.0 start
    Slave device radio configuration example
    #MINT configuration
     mint rf5.0 -name "Slave"
     mint rf5.0 -type slave
     mint rf5.0 -mode fixed
     mint rf5.0 prof 1 -band 20 -freq 5000 -sid 10101010 -type slave -autobitrate -mimo
     mint rf5.0 start
    BS1 device radio configuration example
    #Radio module parameters
     rf rf5.0 band 20
     rf rf5.0 mimo
     rf rf5.0 freq 5100 bitr auto sid 10101010 burst
     rf rf5.0 txpwr max pwrctl distance auto
    
    #MINT configuration
     mint rf5.0 -name "BS1"
     mint rf5.0 -type master
     mint rf5.0 -mode nomadic
     mint rf5.0 start
    BS2 device radio configuration example
    #Radio module parameters
     rf rf5.0 band 20
     rf rf5.0 mimo
     rf rf5.0 freq 5200 bitr auto sid 10101010 burst
     rf rf5.0 txpwr max pwrctl distance auto
    
    #MINT configuration
     mint rf5.0 -name "BS2"
     mint rf5.0 -type master
     mint rf5.0 -mode nomadic
     mint rf5.0 start
    BS3 device radio configuration example
    #Radio module parameters
     rf rf5.0 band 20
     rf rf5.0 mimo
     rf rf5.0 freq 5300 bitr auto sid 10101010 burst
     rf rf5.0 txpwr max pwrctl distance auto
    
    #MINT configuration
     mint rf5.0 -name "BS3"
     mint rf5.0 -type master
     mint rf5.0 -mode nomadic
     mint rf5.0 start
    CPE1 device radio configuration example
    #MINT configuration
     mint rf5.0 -name "AS1"
     mint rf5.0 -type slave
     mint rf5.0 -mode nomadic
     mint rf5.0 prof 1 -band 20 -freq 5100 -sid 10101010 -type slave -autobitrate -mimo
     mint rf5.0 prof 2 -band 20 -freq 5200 -sid 10101010 -type slave -autobitrate -mimo
     mint rf5.0 prof 3 -band 20 -freq 5300 -sid 10101010 -type slave -autobitrate -mimo
     mint rf5.0 start
  • join the backhaul radio network devices into a single MINT area:

    BS1 configuration example
    #Interfaces parameters
     ifc prf0 up
    
    #Pseudo-RF parameters
     prf 0 parent eth0
    
    #MINT configuration
     mint prf0 -name "BS1_prf_eth0"
     mint prf0 -type master
     mint prf0 -mode nomadic
     mint prf0 start
     mint join rf5.0 prf0
    BS2 configuration example
    #Interfaces parameters
     ifc prf0 up
    
    #Pseudo-RF parameters
     prf 0 parent eth0
    
    #MINT configuration
     mint prf0 -name "BS2_prf_eth0"
     mint prf0 -type master
     mint prf0 -mode nomadic
     mint prf0 start
     mint join rf5.0 prf0
    BS3 configuration example
    #Interfaces parameters
     ifc prf0 up
    
    #Pseudo-RF parameters
     prf 0 parent eth0
    
    #MINT configuration
     mint prf0 -name "BS3_prf_eth0"
     mint prf0 -type master
     mint prf0 -mode nomadic
     mint prf0 start
     mint join rf5.0 prf0
    InfiMUX configuration example
    #Interfaces parameters
     ifc prf1 up
     ifc prf2 up
     ifc prf3 up
    
    #Pseudo-RF parameters
     prf 1 parent eth1
     prf 2 parent eth2
     prf 3 parent eth3
    
    #MINT configuration
     mint prf1 -name "InfiMUX_prf_eth1"
     mint prf1 -type master
     mint prf1 -mode nomadic
     mint prf1 start
     mint prf2 -name "InfiMUX_prf_eth2"
     mint prf2 -type master
     mint prf2 -mode nomadic
     mint prf2 start
     mint prf3 -name "InfiMUX_prf_eth3"
     mint prf3 -type master
     mint prf3 -mode nomadic
     mint prf3 start
     mint join prf1 prf2 prf3
  • enable the Global function:

    Global function configuration on CPE1
    #MINT configuration
     mint rf5.0 roaming enable global
    Global function configuration on InfiMUX
    #MINT configuration
     mint prf0 roaming enable global
  • configure the management:

    Management configuration on Master
    #Interfaces parameters
     ifc vlan100 vlan 100 vlandev eth0 up
     ifc svi100 up
     ifc svi100 192.168.100.201/24
    
    #MAC Switch config
     switch group 100 add vlan100 rf5.0
     switch group 100 order 1
     switch group 100 start
    
    #Switch Virtual Interface config
     svi 100 group 100
    Management configuration on Slave
    #Interfaces parameters
     ifc vlan100 vlan 100 vlandev eth0 up
     ifc svi100 up
     ifc svi100 192.168.100.202/24
    
    #MAC Switch config
     switch group 100 add vlan100 rf5.0
     switch group 100 order 1
     switch group 100 start
    
    #Switch Virtual Interface config
     svi 100 group 100
    Management configuration on BS1
    #Interfaces parameters
     ifc svi100 up
     ifc svi100 192.168.100.1/24
    
    #MAC Switch config
     switch group 100 add prf0
     switch group 100 order 1
     switch group 100 start
    
    #Switch Virtual Interface config
     svi 100 group 100
    Management configuration on BS2
    #Interfaces parameters
     ifc svi100 up
     ifc svi100 192.168.100.2/24
    
    #MAC Switch config
     switch group 100 add prf0
     switch group 100 order 1
     switch group 100 start
    
    #Switch Virtual Interface config
     svi 100 group 100
    Management configuration on BS3
    #Interfaces parameters
     ifc svi100 up
     ifc svi100 192.168.100.3/24
    
    #MAC Switch config
     switch group 100 add prf0
     switch group 100 order 1
     switch group 100 start
    
    #Switch Virtual Interface config
     svi 100 group 100
    Management configuration on CPE1
    #Interfaces parameters
     ifc svi100 up
     ifc svi100 192.168.100.101/24
    
    #MAC Switch config
     switch group 100 add rf5.0
     switch group 100 order 1
     switch group 100 start
    
    #Switch Virtual Interface config
     svi 100 group 100
    Management configuration on InfiMUX
    #Interfaces parameters
     ifc vlan100 vlan 100 vlandev eth4 up
     ifc svi100 up
     ifc svi100 192.168.100.200/24
    
    #MAC Switch config
     switch group 100 add vlan100 prf1
     switch group 100 order 1
     switch group 100 start
    
    #Switch Virtual Interface config
     svi 100 group 100
  • configure the service trafic transmission:

    Master configuration example
    #Interfaces parameters
     ifc vlan200 vlan 200 vlandev eth0 up
    
    #MAC Switch config
     switch group 200 add vlan200 rf5.0
     switch group 200 start
    
    Slave configuration example
    #Interfaces parameters
     ifc vlan200 vlan 200 vlandev eth0 up
    
    #MAC Switch config
     switch group 200 add vlan200 rf5.0
     switch group 200 start
    CPE1 Master configuration example
    #Interfaces parameters
     ifc vlan200 vlan 200 vlandev eth0 up
    
    #MAC Switch config
     switch group 200 add vlan200 rf5.0
     switch group 200 start
    InfiMUX configuration example
    #Interfaces parameters
     ifc vlan200 vlan 200 vlandev eth4 up
    
    #MAC Switch config
     switch group 200 add vlan200 prf1
     switch group 200 start