ctl command
The command enables managing the unit’s built-in heater (optional).
Syntax:
ctl [heater threshold|on|off [[no]log]]
- "threshold" - heater enable temperature ( -15...-1 )
The InfiNet Wireless units can be supplied with a built-in heater to enable their operation in very low temperatures and arctic conditions. Such units also has a built-in sensor for the inside temperature.
“ctl” command executed with no additional parameters shows the current temperature inside the unit in Celsius.
“ctl heater threshold” command sets a threshold for the temperature under which the built-in heater is turned on. The range of the threshold temperature varies between -15 and -1 degrees Celsius. For example:
ctl heater threshold -10
“Ctl heater on/off” command turns on or off the heater:
ctl heater on
“Log” option enables registering heater operation events for the sensor in the system log. To disable logging a “nolog” option is used.