All outdoor devices are equipped with indoor power supply units. Exact type of IDU, which is used with each device model is specified in different models description (see below).

Indoor AC/DC injector with integrated lighting protection IDU-CPE

Figure - IDU-CPE top view

IDU-CPE  is an indoor AC/DC PoE injector. It is designed only for R5000-Smn, R5000-Lmn and synchronization hub AUX-ODU-SYNC and has integrated lighting protection.

ParameterDescription
Input voltage (AC)100 ... 240 V
Output voltage+ 48 V, 0.5 A
Power consumption24 W
Ethernet mode10/100 Mbps
Connectors and Interfaces
  • ETH IN - Ethernet input (Data only)
  • ETH OUT - Ethernet output (Data+VDC)
  • PWR - AC Input (100-240 V)
Ethernet Connectors Pin-out
  • ETH IN: 4, 5, 7, 8 - not connected
  • ETH OUT: 4, 5 (+VDC) and 7, 8 (-VDC)
Size and weight87x78x36,5 (LxWxH), 0.15 kg
Operating temperature0 °С ... +40 °С
Lightning protection
  • IEC61000-4-2 (ESD) ±15kV (air), ±8kV (contact)
  • IEC61000-4-4 (EFT) 40A (5/50ns)
  • IEC61000-4-5 (Lightning) 20A (8/20µs)
Table - IDU-CPE Specification

Figure – IDU-CPE Outline Drawing

Indoor AC/DC injector with integrated lighting protection IDU-BS-G

Figure - IDU-BS-G Top View

Indoor Gigabit PoE Injector with lightning protection for InfiLINK 2x2 and InfiMAN 2x2 family (except R5000-Qmxb).

ParameterDescription
Size and weight125*72*38 mm (L*W*H), 0.3 kg
Connectors and Interfaces
  • ETH IN - Ethernet input (Data only)
  • ETH OUT - Ethernet output (Data+VDC), PASSIVE PoE
  • PWR - AC Input (100-240 V)
Supported Ethernet Modes10/100/1000Mbps (Gigabit Ethernet pass-through)
Output Voltage & Current+56 V, 0.9 A (50.4W Max)
Operating temperature range 0 °С ... +40 °С
Ethernet Connectors Pin-outETH INPin12345678
DescriptionA+A-B+C+C-B-D+D-
ETH OUTPin12345678
DescriptionA+A-B++VDC / C++VDC / C-B--VDC / D+-VDC / D-
EMC

Meet:

  • FCC Class B
  • EN55022 Class B
Lightning Protection

In compliance with:

  • IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)
  • IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)
  • IEC 61000-4-5 (Lightning) L5, 95A (tp = 8/20us)
Table - IDU-BS-G Specification

Indoor AC/DC injector with integrated lighting protection IDU-BS-G(60W)

IDU-BS-G (60W)

Figure - IDU-BS-G(60W)

IDU-BS-G(60W) is an indoor AC/DC PoE injector with built-in lightning protection. PoE injector is powered by an AC supply in the 100-240 V range.

ParameterDescription
Compatible modelsInfiLINK XG, InfiLINK XG 1000, InfiLINK 2x2 PRO, InfiMAN 2x2 BS, Quanta 70, Quanta 5, Quanta 6, InfiMAN Evolution BS
Size151*62*38 mm (L*W*H)
Weight0.32 kg
Connectors and Interfaces
  • "ETH IN" - Ethernet input (Data only)
  • "ETH OUT" - Ethernet output (Data+VDC), PASSIVE PoE
  • "PWR" - AC Input
Supported Ethernet Modes
  • 10/100/1000Mbps (Gigabit Ethernet pass-through)
Input Voltage
  • 100 ... 240 V
Output Voltage & Current
  • +55 V, 1.5 A
Consumption
  • 60 W over 4-pairs (Guaranteed)
Operating temperature range
  • -10 °С ... +40 °С
Pin Assignment and Polarity
  • Data Pairs 1/2 (-) and 3/6 (+)
  • Spare Pairs 7/8 (-) and 4/5 (+)
EMC

Meet:

  • FCC Part 15, Class B
  • EN 55022 Class B (Emissions)
  • EN 55024 (Immunity), VCCI
Lightning Protection

In compliance with:

  • IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)
  • IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)
  • IEC 61000-4-5 (Lightning) L5, 95A (tp = 8/20us)
Table - IDU-BS-G(60W) Specification


Figure - IDU-BS-G(60W) Front Panel

 

Figure - IDU-BS-G(60W) Rear Panel

Indoor AC/DC injector IDU-CPE-G(24W)

IDU-CPE-G(24W)_ENG

Figure - IDU-CPE-G(24W)

IDU-CPE-G(24W) is an indoor Gigabit PoE injector which supports 100-240 V input range from the AC mains. IDU-CPE-G(24W) feeds 48 VDC power to the device by injecting it to the CAT5 Ethernet cable.

ParameterDescription
Compatible modelsQuanta 5, Quanta 6, Quanta 70, InfiLINK XG, InfiLINK 2x2 LITE, InfiMAN 2x2 STE, InfiMAN Evolution (except E5-BSQ), InfiLINK Evolution, AUX-ODU-SYNC
Size and weight97*53.5*33.5 mm, 0.133 kg
Connectors and Interfaces
  • "LAN" - Ethernet input (Data only)
  • "POE" - Ethernet output (Data+VDC), PASSIVE PoE
  • "PWR" - AC Input

Supported Ethernet Modes

  • 10/100/1000 Mbps
Standards
  • IEEE 802.3 10Base-T                                                                          
  • IEEE 802.3U 100Base-TX                                                                        
  • IEEE 802.3ab 1000Base-T          
Input Power Requirements
  • AC Input Voltage: 100 ... 240 VAC
  • AC Input Current: 0.75 A
  • AC Frequency: 50 to 60 Hz
Consumption
  • 28 W
Operating temperature range
  • -10 °С ... +40 °С
Operating humidity
  • Maximum 95 %, Non-condensing
Storage temperature
  • -40 °С ... +70 °С
Output Power Voltage
  • 48 VDC, 0.5 A
Ethernet Connectors Pin-outLANPin12345678
DescriptionA+A-B+C+C-B-D+D-
POEPin12345678
DescriptionA+A-B++VDC / C++VDC / C-B--VDC / D+-VDC / D-
Safety
  • UL cUL, CE, GS, CCC, FCC, S-MARK, PSE, C-tick, KC(48V0.5A) BIS(24V1A)




Table - IDU-CPE-G(24W) Specification

Indoor DC/DC injector with integrated lightning protection IDU-CPE-DC

Figure - IDU-CPE-DC top view

IDU-CPE-DC is an indoor DC/DC injector. It greatly reduces complexity of the deployment in the cases where DC source is available thus reducing both capital expenditures and total cost of ownership. It is desinged for all CPE units (Smn and Lmn) and has integrated lightning protection. The source of DC power supply can be +48 V or even -48 V, hence installation of CPE units is possible where other DC or AC power sources are unavailable.

ParameterDescription
Compatible modelsR5000-Smn and R5000-Lmn
Connectors and Interfaces
  • "Switch HUB" - Ethernet input (Data only)
  • "RJ45" - Ethernet output (Data+VDC), protected leg
  • "VIN+" - DC+ Input
  • "VIN–" - DC– Input
  • "FG" - ground clamp
Supported Ethernet Modes
  • 10/100 Mbps (Fast Ethernet pass-through)
Input voltage
  • ±36 ... 72 V
Output voltage
  • +48 V, 0.5 A
Power consumption
  • 24 W
Ethernet Connectors Pinout
  • "Switch HUB": 4, 5, 7, 8 - not connected
  • "RJ45": 4, 5 (+VDC) and 7, 8 (-VDC)
Lightning
  • IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)
  • IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)
  • IEC 61000-4-5 (Lightning), 20A (tp = 8/20us)
EMCFCC Class B , EN55022 Class B, EN60945, EN50155
SafetyUL1950, CSA 22.2 & TUV EN60950
Size and Weight85x57x36 mm, 0.15 kg
Table - IDU-CPE-DC Specification

Figure - Connection scheme

Indoor DC/DC injector with integrated lightning protection IDU-LA-G(V.01)

IDU-LA-G(V.01) is an indoor DC/DC injector. It greatly reduces complexity of the deployment in the cases where DC source is available thus reducing both capital expenditures and total cost of ownership.

IDU-LA-G(V.01) may be used for the following purposes:

  • To serve as a line protection unit for indoor network equipment connected to the second Ethernet port on ODU.
  • To connect third-party DC power sources to ODU (for example, to power the unit from solar power or wind power sources).

Technical parameters

ParameterDescription
Compatible modelsInfiLINK XG, InfiLINK XG 1000, InfiLINK 2x2, InfiMAN 2x2, Quanta 5, Quanta 6, Quanta 70, InfiLINK Evolution, InfiMAN Evolution
Output VoltageThe same as input
Supported Ethernet Modes10/100/1000 Mbps (Gigabit Ethernet pass-through)
Pin assignment and polarity1/2 (+), 3/6 (-), 4/5 (+), 7/8 (-)
DC RangeAcceptable input DC range depends on the specific ODU model:
InfiLINK XG, InfiLINK XG 1000, InfiLINK 2x2 PRO, InfiMAN 2x2 BS, Quanta 70, Quanta 5, Quanta 6, InfiLINK Evolution, InfiMAN Evolution models: ±43... ±56 VDC
InfiLINK 2x2 Lite, InfiMAN 2x2 STE models: +9... +56 VDC (positive voltage only)
Size and Weight115×65×40 mm, 0.15 kg
Operating temperature rangefrom 0°С to +40°С

CAUTION

Exposing unit to the unsupported voltage will result in irreparable damage to the unit! Always observe power requirements!

Connectors description

IDU-LA-G(V.01)_eng

Mounting holes sizes

IDU-LA-G(V.01)_mounting holes

IDU-LA-G(V.01) Packing List

IDU-LA-G(V.01)_Packing list

Cable assembly

Cable Inf-cable-001

Outdoor DC/DC injector with lightning protection AUX-ODU-INJ-G

Figure - AUX-ODU-INJ-G

Optional indoor/outdoor DC injector with built-in lightning protection. It greatly reduces complexity of the deployment in the cases where DC source is available on the rooftop eliminating the need of weather-sealed cabinets. AUX-ODU-INJ-G is compatible with all Infinet Wireless devices.

ParameterDescription
Size and Weight34x94x121 mm, 0.28 kg
Connectors and Interfaces
  • ETH IN - Ethernet input
  • ETH OUT - Ethernet output (data+VDC, protected leg)
  • PWR - DC Input
  • GND - Ground clamp
Supported Ethernet Modes
  • 10/100/1000 Mbps (Gigabit Ethernet pass-through)
Water and Dust Protection
  • IP66 and IP67
Operating temperature range
  • -55 °C ... +60 ºC
DC Range
  • InfiLINK XG, InfiLINK XG 1000, InfiLINK 2x2 PRO, InfiMAN 2x2 BS, Quanta 70, Quanta 5, Quanta 6, InfiLINK Evolution, InfiMAN Evolution: ±43...±56 VDC 
  • InfiLINK 2x2 Lite, InfiMAN 2x2 STE: +9... +56 VDC (positive voltage only)

CAUTION

Using inappropriate DC source will damage the ODU, which will be not covered by warranty

Ethernet Connectors Pin-outETH INPin12345678
DescriptionData pair A+Data pair A-Data pair B+Data pair C-Data pair C+Data pair B-Data pair D+Data pair D-
ETH OUTPin12345678
DescriptionData pair A+Data pair A-Data pair B++VDC + Data pair C-+VDC + Data pair C+Data pair B--VDC + Data pair D+-VDC + Data pair D-
Lightning Protection

In compliance with:

  • GR-1089
  • IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)
  • IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)
  • IEC 61000-4-5 (Lightning) L5, 95A (tp = 8/20us)
  • ETSI ETS 300 386
Table - AUX-ODU-INJ-G Specifications

Packing List

AUX-ODU-INJ Packing List

AUX-ODU-INJ-G is supplied with a worm clamp TORRO 40-60/9 C7 W4 DIN 3017 - 2 pcs. The clamp is made of stainless steel A4, width 9 mm, allows the installation on a mast with a diameter of 35 to 60 mm. In case of mast diameter more than 60 mm, a similar clamps (up to a 230 mm diameter) with a width of up to 12-13 mm can be used.