Page tree
Skip to end of metadata
Go to start of metadata

RapidView-1 – is a special diagnostic device that is used for InfiNet Wireless equipment comfort installation, antenna alignment and configuration.

Device allows getting the following information:

  • Radio link establishment indication
  • Visual monitoring of radio signal levels
  • Receiving retries information
  • Diagnostic of RF and Ethernet interfaces.

Figure - RapidView-1 top view

Figure - RapidView-1 back view

Figure - RapidView-1 Indicator panel

How to use

  1. For turning RapidView-1 on simply push «Power button»
  2. Device LEDs will light up for 2 seconds
  3. Device will perform constant tries to connect to ODU. If device’s power is normal Power/ODU connection LED (1) will blink 1 time per second. If device’s power is low LED 1 will blink 4 times per second in turn with not lighting intervals.
  4. Once ODU link is established LED 1 stops blinking (if power is normal) and device’s interfaces status are shown by LEDs 2-6.
  5. 1 time per second device updates its status output.
  6. If ODU link will be broken LEDs 2-6 will go out after 2 seconds and LED 1 will start blinking 1 time per second.

Diagnostic device connection to ODU should be done via console port of the ODU. Once link is up between ODU and diagnostic device the following record is put in ODU system log:

  • Connected test unit. Begin service communication over console
  • Test unit detected: rf0 – rf5.0

Exact radio interface names depend on wireless equipment configuration.

When diagnostic device is unplugged from the following record is put in ODU system log:

Test unit disconnected. Return to normal console mode.

LEDs modes description

ODU status monitoring via diagnostic device is performed by its LEDs indication. LEDs modes and ODU status correspondence is shown in the following table

LEDFunction
Power/ODU connection LED

Shows diagnostic device power status and diagnostic device-ODU connection status:

  • Constant lighting — diagnostic device-ODU connection established, diagnostic device power is normal
  • Blinking 1 time per second — diagnostic device power is normal, diagnostic device-ODU connection is not established
  • Blinking 4 times per second — diagnostic device-ODU connection established, diagnostic device power is low (change batteries)
  • Frequent blinking with intervals — diagnostic device power is low, diagnostic device-ODU connection is not established
Radio link LEDs

Shows whether radio link is established on certain ODU’s radio interface:

  • Constant lighting — radio link is established.

 What ODU’s radio interface to show by what column RF0 or RF1 is chosen by the following way:

  • for RF0 column is taken radio interface with the least number
  • for RF1 the other interface.

For example, there are the following radio interfaces on ODU: Rf5.0, rf5.1. Then for RF0 column rf5.0 will be taken, for RF1 — rf5.1.

 When no radio link then LEDs 2-4 are not lighting

Radio signal overload/Packets retries LEDs

Shows receiving radio signal level overload and number of packet retries information:

  • Constant lighting —receiving radio signal level on the interface is too high.
  • Blinking 4 times per second -  number of retries >= 50%
  • Blinking 2 times per second -  number of retries >= 28 %
  • Blinking 1 time per second -  number of retries >= 7 %

If certain radio interface (radio module) is not present on the device then all corresponding LEDs of this radio interface is off.

If ODU has certain radio interface but it is not activated (for example, not entered «mint rf5.0 start» command) then LED 3 is blinking 1 time per second whereas LEDs 2 and 4 are not lighting.

If ODU has certain radio interface but it is not activated (for example, not entered «mint rf5.0 start» command) then LED 3 is blinking 1 time per second whereas LEDs 2 and 4 are not lighting.

If ODU has certain radio interface activated («mint rf5.0 start» command entered) then LED 3 is blinking 4 times per second whereas LEDs 2 and 4 are not lighting

Radio signal level scales

Shows receiving signal level of the established radio link.

 Each LED can be in 3 modes:

  • Not lighting — radio signal level is lower than scale value
  • Blinking — the more frequently is blinking the nearer signal level is to given scale value
  • Constant lighting — signal level is higher or equal to scale value
Ethernet interface data rate LEDs 

Shows data rate of the corresponding Ethernet interface.

There are 2 LEDs for each Ethernet interface (Eth0 and Eth1)


10 Mbps100 Mbps1000 MbpsError
Upper LEDLightingNot lightingLightingBlinking
Lower LEDNot lightingLightingLightingBlinking
Ethernet interface mode LEDs
  • Constant lighting — Full Duplex
  • Not lighting — Half Duplex.

 IF Ethernet connection is established but corresponding ODU’s interface is not enabled then LEDs 5, 6 indicate connection configuration by blinking 1 time per second