Required components are listed below.
- Unshielded RJ-45 connector.
- Shielded RJ-45 connector.
- FTP Cat5e cable.
- Cable gland:
- Cable sealing nut.
- Cable sealing grommet with rubber seal.
- Cable gland case.
- Crimping tool for RJ-45 connector.
Note |
---|
|
The outside diameter value of the FTP Cat5e cable should not exceed 7 mm. |
Assemble procedure
Anchor |
---|
| Assemble procedure |
---|
| Assemble procedure |
---|
|
In order to ensure that the device case remains sealed under any environmental conditions follow the assemble procedure:
- Step 1: Insert the sealing insert into the clamping claw.
- Step 2: Assemble the cable gland by putting the thread-lock sealing nut, clamping claw with sealing insert and body onto the cable as shown on the figure.
- Step 3: Insert the clamping claw with sealing insert into the body as shown on the figure.
- Step 4: Crimp the standard RJ-45 connector onto the cable using crimping tool. Pin-out scheme: T568B wiring standards
Note |
---|
|
Do not use the shielded RJ-45 connector on this end of the cable as it should be attached on the power supply unit end. |
Warning |
---|
|
Make sure that the RJ-45 connector is well-crimped. A loose connector can damage the device. Please note that such damage is not covered by the warranty. |
- Step 5: Insert the Rj-45 connector into the device socket until you hear a click.
- Step 6: Screw the cable gland body into the port and tighten it. Do not apply excessive force.
- Step 7: Tighten the thread-lock sealing nut. Do not apply excessive force.
Gliffy Diagram |
---|
displayName | cable assembling Copy |
---|
name | cable assembling Copy |
---|
pagePin | 1 |
---|
|