The surface on which the devices is installed must support the outdoor unit and power adapter weight. There must be enough space around the outdoor unit for ventilation air flow and free access to the cable connectors: at least 15 cm on the side of the power adapter connection, cables and ventilation fins, and 5 cm on the other two sides. The operating temperature and humidity values must be within the permissible limits at the installation site of the device.

...

The outdoor unit can be mounted on a rack using L-shaped rackmounting brackets (is not supplied by default). Before installation please read the precautions first. 

  • Elevated Operating Ambient. If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature specified by the manufacturer.
  • Reduced Air Flow. Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Mechanical Loading: mounting of the equipment in the rack should be such that a hazardous condition is not created due to uneven mechanical loading.
  • Circuit Overloading. Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over-current protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
  • Reliable Grounding. Reliable grounding of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit.
Note
titleNOTE

Slide/rail mounted equipment is not to be used as a shelf or a work space.

After reading the precautions, please see the following for mounting on a rack:

  • Prepare the L-shaped rackmounting brackets.
  • Attach the L-shaped brackets to the screw holes on eachside of the outdoor unit. Apply screws to secure the brackets until totally fixed.

Image Added

  • Attach the ears of the L-shaped brackets to the rack and then apply long threaded nails. Repeat this for another side.

Image Added

Power adapter connection

...