Page tree

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Run the ERConsole.jar application downloaded from our FTP.
  2. Connect a network Ethernet cable between the InfiNet Wireless unit and your PC.
  3. Turn off the InfiNet Wireless unit and then turn it on in a few seconds
  4. Wait for 30 seconds and the ERConsole screen should receive update from the unit as it's shown on the figure below. The Serial number, number of device reset cycles ("Sequence" field),  IP address, network mask and MAC-adress will be displayed on the screen:

    Center
    Scroll Title
    title Figure - ERConsole information

  5. If an IP address is assigned to the unit, configure on your laptop an IP from  belonging to the same network class and  and connect to the unit in order to perform the modifications and checking required. If there is no IP displayed (0.0.0.0), proceed with the next step
  6. If there is more than one unit in the list, please, select the required unit.
  7. Click the «+» button in the ERConsole application and a new window will appear
  8. In the New task window, set the additional IP address and network mask, then click «OK» like below:

    Center
    Scroll Title
    titleFigure - Adding a new IP address

  9. Turn off and on the InfiNet unit. Wait for about 30 seconds until the IP is assigned
  10. Add an IP address from the same network subnet to your PC and access the unit. ERC will not show newly assigned IP address
  11. Login to the unit using the new IP. Do not reboot the unit now because the additional IP address is temporar until the next restart or the new configuration has been saved.

...

  1. Obtain the IP-address of the unit using the ERConsole as described in the section above.
  2. Click on the «+» button in the ERConsole application and a new window will appear.
  3. Obtain the Factory Password. In order to do this, please contact the distributor through whom the device was purchased, or in case purchasing the unit directly in InfiNet Wireless, send a request to the InfiNet Technical support to support@infinetwireless.com. The request must include the device serial number and the value of "Sequence" field (if it's non-zero).
  4. Select “Reset configuration” option and enter the Factory Password obtained at the previous step in the "Factory password" field, then click «OK». The password must be entered the same format as you've got it format as it has been got it from the distributor or IW support (with the gaps).
  5. Turn off and on the unit and then wait for about 30 seconds.
  6. The unit will start in special emergency mode with the IP-address 10.10.10.1 and mask 255.255.255.0.
  7. Login to the unit and set new login and password, then save the configuration and restart the unit via "Maintenance" page.