One unit of link must be set to Master and the other one to Slave. Slave unit will inherit radio settings from Master unit. Automatic selectio At the link initial phase the following parameters must be set to the same values on Master unit and Slave unit: - Center frequency - it may be set by two ways:
- Manually via Downlink center frequency and Uplink center frequency parameters. In this case link will be setup at once.
- Automatically with "Automatic selection of center frequency" function. In this case frequency channel grids must be set on both units. At the initial phase Master unit will select its center frequency automatically, after that Slave unit will scan frequencies from its grids and link will be setup when Slave find the center frequency which Master operates on.
|