This section allows to monitor radio lonk link parameters. The link status and main settings are displayed on top of this section, the bottom part shows statistic for Master and Slave unit, both uplink and downlink direction, in case of InfiLINK XG 1000 family, the information is shown for both carriers. 

...

Displays Carrier to Interference and Noise Ratio measured in downlink and expressed in dB. CINR can be limited either due to too low signal level or because of the interference from other radios. In order to reach highest modulations, values higher or equal to 28 dB are required.

...

Performs a scan of the electromagnetic spectrum in the desired frequency range and provides detailed information about the emitting sources present in the area. While the test is being performed the link is disconnected and the unit will function operate in listening mode only. Interferences can be easily spotted this way. Interference pulses are displayed for the frequencies that are pollutedbusy. By pointing over the desired pulse, detailed information will be displayed about the strength of the interference: input level, max and average RSSI. The scan is available based on customized parameters: start/stop frequency, band, step, and scan duration.

...