  1. Screw the threaded rod to the unit case.
  2. Tighten the device and the bracer on the pole and fix them by the threaded rod using the nuts and washers as shown at the picture
  3. Attach the grounding cable to the unit case using the grounding bolt.
Center

Gliffy Diagram
displayNameAUX-ODU-SYNC Installation
nameAUX-ODU-SYNC Installation
pagePin3

Warning
titleCAUTION

 Missing or bad grounding may leave the unit vulnerable to lightning damage.

...

Center
Scroll Title
titleFigure - Cable gland Assembling scheme

Warning
titleCAUTION

Please note that the pressure equalization system in Infinet devices is performed via gas exchange through a cable gland and Ethernet cable jacket with a dry room where the power supply is installed. In order to avoid AUX-ODU-SYNC failure due to moisture entering the device, for example, during the pressure drop during the rain, the cable gland assembly requirements should be met and there are should be no cracks in the Ethernet cable jacket.

In addition, you should avoid the Ethernet cable bending near the AUX-ODU-SYNC and pinching with clamps, that can bring to the pressure equalization system fault between the internal volume of the sealed AUX-ODU-SYNC and the external environment during a sudden air temperature change. This may lead to the leakage and device failures.

AUX-ODU-SYNC Connection to ODU

...