IDU-LA-G(V.01) is an indoor DC/DC injector. It greatly reduces complexity of the deployment in the cases where DC source is available thus reducing both capital expenditures and total cost of ownership.

IDU-LA-G(V.01) may be used for the following purposes:

  • To serve as a line protection unit for indoor network equipment connected to the second Ethernet port on ODU.
  • To connect third-party DC power sources to ODU (for example, to power the unit from solar power or wind power sources).

Technical parameters

ParameterDescription
Compatible modelsInfiLINK XG, InfiLINK XG 1000, InfiLINK 2x2, InfiMAN 2x2, Quanta 5, Quanta 6, Quanta 70, InfiLINK Evolution, InfiMAN Evolution
Output VoltageThe same as input
Supported Ethernet Modes10/100/1000 Mbps (Gigabit Ethernet pass-through)
Pin assignment and polarity1/2 (+), 3/6 (-), 4/5 (+), 7/8 (-)
DC RangeAcceptable input DC range depends on the specific ODU model:
InfiLINK XG, InfiLINK XG 1000, InfiLINK 2x2 PRO, InfiMAN 2x2 BS, Quanta 70, Quanta 5, Quanta 6, InfiLINK Evolution, InfiMAN Evolution models: ±43... ±56 VDC
InfiLINK 2x2 Lite, InfiMAN 2x2 STE models: +9... +56 VDC (positive voltage only)
Size and Weight115×65×40 mm, 0.15 kg
Operating temperature rangefrom 0°С to +40°С

CAUTION

Exposing unit to the unsupported voltage will result in irreparable damage to the unit! Always observe power requirements!