Page tree
Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Successfully pass the free certification exam at IW Academy and become an Infinet Certified Engineer.

To the certification exam

Indoor AC/DC injector IDU-CPE-G(24W)

IDU-CPE-G(24W)_ENG

Figure - IDU-CPE-G(24W)

IDU-CPE-G(24W) is an indoor Gigabit PoE injector which supports 100-240 V input range from the AC mains. IDU-CPE-G(24W) feeds 48 VDC power to the device by injecting it to the CAT5 Ethernet cable.

ParameterDescription
Compatible modelsQuanta 5, Quanta 6, Quanta 70, InfiLINK XG, InfiLINK 2x2 LITE, InfiMAN 2x2 STE, InfiMAN Evolution (except E5-BSQ), InfiLINK Evolution, AUX-ODU-SYNC
Size and weight97*53.5*33.5 mm, 0.133 kg
Connectors and Interfaces
  • "LAN" - Ethernet input (Data only)
  • "POE" - Ethernet output (Data+VDC), PASSIVE PoE
  • "PWR" - AC Input

Supported Ethernet Modes

  • 10/100/1000 Mbps
Standards
  • IEEE 802.3 10Base-T                                                                          
  • IEEE 802.3U 100Base-TX                                                                        
  • IEEE 802.3ab 1000Base-T          
Input Power Requirements
  • AC Input Voltage: 100 ... 240 VAC
  • AC Input Current: 0.75 A
  • AC Frequency: 50 to 60 Hz
Consumption
  • 28 W
Operating temperature range
  • -10 °С ... +40 °С
Operating humidity
  • Maximum 95 %, Non-condensing
Storage temperature
  • -40 °С ... +70 °С
Output Power Voltage
  • 48 VDC, 0.5 A
Ethernet Connectors Pin-outLANPin12345678
DescriptionA+A-B+C+C-B-D+D-
POEPin12345678
DescriptionA+A-B++VDC / C++VDC / C-B--VDC / D+-VDC / D-
Safety
  • UL cUL, CE, GS, CCC, FCC, S-MARK, PSE, C-tick, KC(48V0.5A) BIS(24V1A)




Table - IDU-CPE-G(24W) Specification

Indoor AC/DC injector with integrated lightning protection IDU-BS-G(60W)

IDU-BS-G (60W)

Figure - IDU-BS-G(60W)

IDU-BS-G(60W) is an indoor AC/DC PoE injector with built-in lightning protection. PoE injector is powered by an AC supply in the 100-240 V range.

ParameterDescription
Compatible modelsInfiLINK XG, InfiLINK XG 1000, InfiLINK 2x2 PRO, InfiMAN 2x2 BS, Quanta 70, Quanta 5, Quanta 6, InfiMAN Evolution BS
Size151*62*38 mm (L*W*H)
Weight0.32 kg
Connectors and Interfaces
  • "ETH IN" - Ethernet input (Data only)
  • "ETH OUT" - Ethernet output (Data+VDC), PASSIVE PoE
  • "PWR" - AC Input
Supported Ethernet Modes
  • 10/100/1000Mbps (Gigabit Ethernet pass-through)
Input Voltage
  • 100 ... 240 V
Output Voltage & Current
  • +55 V, 1.5 A
Consumption
  • 60 W over 4-pairs (Guaranteed)
Operating temperature range
  • -10 °С ... +40 °С
Pin Assignment and Polarity
  • Data Pairs 1/2 (-) and 3/6 (+)
  • Spare Pairs 7/8 (-) and 4/5 (+)
EMC

Meet:

  • FCC Part 15, Class B
  • EN 55022 Class B (Emissions)
  • EN 55024 (Immunity), VCCI
Lightning Protection

In compliance with:

  • IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)
  • IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)
  • IEC 61000-4-5 (Lightning) L5, 95A (tp = 8/20us)
Table - IDU-BS-G(60W) Specification


Figure - IDU-BS-G(60W) Front Panel

 

Figure - IDU-BS-G(60W) Rear Panel

Indoor DC/DC injector for all InfiNet Wireless' units with integrated lightning protection IDU-LA-G(V.01)

IDU-LA-G(V.01) is an indoor DC/DC injector. It greatly reduces complexity of the deployment in the cases where DC source is available thus reducing both capital expenditures and total cost of ownership.

IDU-LA-G(V.01) may be used for the following purposes:

  • To serve as a line protection unit for indoor network equipment connected to the second Ethernet port on ODU.
  • To connect third-party DC power sources to ODU (for example, to power the unit from solar power or wind power sources).

Technical parameters

ParameterDescription
Compatible modelsInfiLINK XG, InfiLINK XG 1000, InfiLINK 2x2, InfiMAN 2x2, Quanta 5, Quanta 6, Quanta 70, InfiLINK Evolution, InfiMAN Evolution
Output VoltageThe same as input
Supported Ethernet Modes10/100/1000 Mbps (Gigabit Ethernet pass-through)
Pin assignment and polarity1/2 (+), 3/6 (-), 4/5 (+), 7/8 (-)
DC RangeAcceptable input DC range depends on the specific ODU model:
InfiLINK XG, InfiLINK XG 1000, InfiLINK 2x2 PRO, InfiMAN 2x2 BS, Quanta 70, Quanta 5, Quanta 6, InfiLINK Evolution, InfiMAN Evolution models: ±43... ±56 VDC
InfiLINK 2x2 Lite, InfiMAN 2x2 STE models: +9... +56 VDC (positive voltage only)
Size and Weight115×65×40 mm, 0.15 kg
Operating temperature rangefrom 0°С to +40°С

CAUTION

Exposing unit to the unsupported voltage will result in irreparable damage to the unit! Always observe power requirements!

Connectors description

IDU-LA-G(V.01)_eng

Mounting holes sizes

IDU-LA-G(V.01)_mounting holes

IDU-LA-G(V.01) Packing List

IDU-LA-G(V.01)_Packing list

Cable assembly

Cable Inf-cable-001

Lightning Protection Unit with Injector AUX-ODU-INJ-G

Figure - AUX-ODU-INJ-G

Optional indoor/outdoor DC injector with built-in lightning protection. It greatly reduces complexity of the deployment in the cases where DC source is available on the rooftop eliminating the need of weather-sealed cabinets. AUX-ODU-INJ-G is compatible with all Infinet Wireless devices.

ParameterDescription
Size and Weight34x94x121 mm, 0.28 kg
Connectors and Interfaces
  • ETH IN - Ethernet input
  • ETH OUT - Ethernet output (data+VDC, protected leg)
  • PWR - DC Input
  • GND - Ground clamp
Supported Ethernet Modes
  • 10/100/1000 Mbps (Gigabit Ethernet pass-through)
Water and Dust Protection
  • IP66 and IP67
Operating temperature range
  • -55 °C ... +60 ºC
DC Range
  • InfiLINK XG, InfiLINK XG 1000, InfiLINK 2x2 PRO, InfiMAN 2x2 BS, Quanta 70, Quanta 5, Quanta 6, InfiLINK Evolution, InfiMAN Evolution: ±43...±56 VDC 
  • InfiLINK 2x2 Lite, InfiMAN 2x2 STE: +9... +56 VDC (positive voltage only)

CAUTION

Using inappropriate DC source will damage the ODU, which will be not covered by warranty

Ethernet Connectors Pin-outETH INPin12345678
DescriptionData pair A+Data pair A-Data pair B+Data pair C-Data pair C+Data pair B-Data pair D+Data pair D-
ETH OUTPin12345678
DescriptionData pair A+Data pair A-Data pair B++VDC + Data pair C-+VDC + Data pair C+Data pair B--VDC + Data pair D+-VDC + Data pair D-
Lightning Protection

In compliance with:

  • GR-1089
  • IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)
  • IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)
  • IEC 61000-4-5 (Lightning) L5, 95A (tp = 8/20us)
  • ETSI ETS 300 386
Table - AUX-ODU-INJ-G Specifications

Packing List

AUX-ODU-INJ Packing List

AUX-ODU-INJ-G is supplied with a worm clamp TORRO 40-60/9 C7 W4 DIN 3017 - 2 pcs. The clamp is made of stainless steel A4, width 9 mm, allows the installation on a mast with a diameter of 35 to 60 mm. In case of mast diameter more than 60 mm, a similar clamps (up to a 230 mm diameter) with a width of up to 12-13 mm can be used.

  • No labels