Figure - IDU-LA-G top view
IDU-LA-G is an indoor DC/DC injector. It greatly reduces complexity of the deployment in the cases where DC source is available thus reducing both capital expenditures and total cost of ownership.
IDU-LA-G may be used for the following purposes:
- To serve as a line protection unit for indoor network equipment connected to the second Ethernet port on ODU
- To connect third-party DC power sources to ODU (for example, to power the unit from solar power or wind power sources).
In both cases IDU-LA-G should be properly grounded (please refer to the “Grounding and Lightning Protection” section of this manual).
Figure - IDU-LA-G front panel view
Figure - IDU-LA-G inside view
Size 115×65×40 mm (L×W×H)
Figure - Mounting holes sizes
Supported power ratings for R5000 models
Model | Power rating |
---|---|
R5000-Smn R5000-Lmn | +9VDC…+56VDC |
R5000-Mmx R5000-Omx InfiLINK XG | ±43VDC…±56VDC |
Table - Power ratings for R5000 models
CAUTION
Exposing unit to the unsupported voltage will result in irreparable damage to the unit! Always observe power requirements!
IDU-LA-G Packing List
Component | Description |
---|---|
| |
| |
| |
|
Table - IDU-LA-G Packing List