Page tree
Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 46 Current »

Successfully pass the free certification exam at IW Academy and become an Infinet Certified Engineer.

To the certification exam

Wireless device

The wireless device contains both the radio and networking electronics. Implemented in a robust all-weather metal enclosure, this equipment can be used to create point-to-point wireless links at distances in excess of 10 km (depending on weather conditions, interference, terrain, climate zones, etc.). The wireless device is supplied in the following configuration: integrated lens antenna with an antenna gain 39 dBi.

Q70_equipment

Grounding bolt

For grounding the wireless device to the supporting structure.

Interfaces

Quanta 70 has network combo port: gigabit Ethernet and SFP. Only one port can be used for data transmission at a time.

NOTE

Please note, the SFP port has priority in case both ports are enabled.

InterfaceDescription
Gigabit EthernetRJ45 socket for connecting to power supply and data transmission. The network connection to the wireless device is made via a 1000BaseT (Gigabit) Ethernet connection. Power is provided to the device over the 1000BaseT Ethernet connection using a standard IEEE 802.3at passive PoE power supply.
SFPExternal optical Gigabit port for plugging of the optical SFP transceiver module.

LEDs

NOTE

Power and wired statuses indication is performed via glassy plug of the cable gland.

LEDStateStatusDescription
RSSINumberRX Signal value

Values on the RSSI LED are displayed in negative (-) dBm. For example, 90 represents a received signal level of -90 dBm. Lower values indicate stronger received signal levels.

— —Wireless link is not established

Gigabit Ethernet

SFP

FlashInitializationThe LEDs on both ports light up with white on second. Then LEDs check is performed: red, blue, green are lightened up sequentially.
FlashLoadingOnly for Gigabit Ethernet port: at the beginning green is lightened a few seconds, on the second loading stage switches to blue.
ON/BluePowerOnly for Gigabit Ethernet port.
ON/RedSpeed 10 MbpsOnly for Gigabit Ethernet port.
ON/YellowSpeed 100 MbpsOnly for Gigabit Ethernet port.
ON/GreenSpeed 1000 Mbps
ON/Green

ERConsole stage

Port with the established link lights up with green, the second port remains blue.
Ethernet Indication

Part number description

Quanta 70 part number has the following structure
Quanta Part Number_1

Structure items are described below

ItemDescription
1Product family name:
  • Q - Quanta.
2Frequency range:
  • 70 - device in the range of 70 GHz.

3
  • 39 - antenna with 39 dBi gain;
  • 50 - antenna with 50 dBi gain.