Cable Gland Assembly

Required components:

  1. FTP Cat5e cable;
  2. Unshielded RJ-45 connector;
  3. Shielded RJ-45 connector;
  4. Cable gland nut;
  5. Split sealing grommet;
  6. Cable gland threaded coupling.



The outside diameter value of the FTP Cat5e cable should not exceed 7 mm.

Cable gland can be assembled on pre-crimped cable.

Step 1


  • Crimp the unshielded RJ-45 connector (2) onto the cable using the crimping tool.

Pin-out scheme: T568B wiring standards

Do not use the shielded RJ-45 connector on this end of the cable as it should be attached on the IDU end.

MAKE SURE THAT THE RJ-45 CONNECTOR IS WELL-CRIMPED. A LOOSE CONNECTOR CAN DAMAGE THE DEVICE. PLEASE NOTE THAT SUCH DAMAGE IS NOT COVERED BY THE WARRANTY.

Step 2


  • Put the cable gland nut (4), the split sealing grommet (5) and the cable gland threaded coupling (6) onto the pre-terminated cable.

Step 3


  • Insert the split sealing grommet (5) into the cable gland threaded coupling (6).

Step 4


  • Insert the connector into the socket until you hear a click.

Step 5


  • Screw the cable gland threaded coupling (6) into the port and tighten it.

Step 6


  • Tighten the cable gland nut (4). Do not apply excessive force.





Cable Gland Assembly for Optical Cable

SFP module is not included into the packing list. Is possible to use an SFP (Small Form-factor Pluggable) transceiver of any manufacturer that meets the MSA (MultiSource Agreement) standard.

Required components:

  1. Optical cable
  2. Optical connector
  3. SFP-module
  4. Cable gland nut
  5. Split sealing grommet
  6. Cable gland threaded coupling.

Step 1


  • Put the cable gland nut (4), the split sealing grommet (5) and cable gland threaded coupling (6) onto the pre-terminated optical cable (1).

Step 2


  • Insert the split sealing grommet (5) into the cable gland threaded coupling (6).

Step 3


  • Set the SFP-module (3) into the socket until you hear a click.

Step 4


  • Insert the optical connector into the SFP-module (3).

Step 5


  • Screw the cable gland threaded coupling (6) into the port and tighten it.

Step 6


  • Tighten the cable gland nut (4). Do not apply excessive force.

In order to disassemble SFP, please disconnect the optical cable, pull the clip of the SFP-module and withdraw the SFP-module from the slot.