Tables and charts with laboratory testing result data are shown below. The devices with TDMA software version were used while testing. Devices settings that did not change during testing:

Delay value dependence on maximum distance with fixed frame period (channel width - 40MHz, modulation - QAM64 5/6)

Frame period

2 ms10 ms
Load

Subscribers
number


Max. distanceMax. distance
1 km100 km1 km100 km


10%

5991313
1519192124
2439283032


90%

52214110131
155824161171
242743138319

Frame period 2 ms

Subscribers
number

1100
5 CPE99
15 CPE1919
24 CPE3928

Subscribers
number

1100
5 CPE2214
15 CPE5824
24 CPE2743

Frame period 10 ms

Subscribers
number
1100
5 CPE1313
15 CPE2124
24 CPE3032
Subscribers
number
1100
5 CPE110131
15 CPE161171
24 CPE138319

Delay value dependence on maximum distance with fixed subscribers number (channel width - 40MHz, modulation - QAM64 5/6)

Subscribers
number
524

Load

Frame period

Max. distanceMax. distance
1 km100 km1 km100 km


10%

2 ms993928
6 ms992426
10 ms13133032


90%

2 ms22142743
6 ms4642107100
10 ms110131138319

Subscribers number - 5

Frame period1100
2 ms99
6 ms99
10 ms1313
Frame period1100
2 ms2214
6 ms4642
10 ms110131

Subscribers number - 24

Frame period1100
2 ms3928
6 ms2426
10 ms3032
Frame period1100
2 ms2743
6 ms107100
10 ms138319