Optional indoor/outdoor Lightning Protection Unit for Infinet Wireless systems designed to withstand the toughest conditions and protect the outdoor or the indoor unit from sudden power surges induced by lightning strikes. It provides the same level of protection as AUX-ODU-INJ-G.
Despite the fact every Infinet Wireless unit has a built-in lightning protection, AUX-ODU-LPU-G, thanks to its superior GR-1089-grade protection, greatly reduces the risk of replacing damaged devices operating in harsh environments or difficult-to-reach locations.
The device is not supplied by default and must be ordered separately. |
Parameter | Description |
---|
Size and Weight | | Connectors and Interfaces | - ETH IN - Ethernet input
- ETH OUT - Ethernet output (protected leg)
- GND - Ground clamp
| Supported Ethernet Modes | - 10/100/1000 Mbps (Gigabit Ethernet pass-through)
| Water and Dust Protection | | Operating temperature range | | Ethernet Connectors Pin-out | ETH IN | ETH OUT |
---|
Pin | Description | Pin | Description |
---|
1 | Data pair A+ | 1 | Data pair A+ |
---|
2 | Data pair A- | 2 | Data pair A- |
---|
3 | Data pair B+ | 3 | Data pair B+ |
---|
4 | Data pair C- | 4 | Data pair C- |
---|
5 | Data pair C+ | 5 | Data pair C+ |
---|
6 | Data pair B- | 6 | Data pair B- |
---|
7 | Data pair D+ | 7 | Data pair D+ |
---|
8 | Data pair D- | 8 | Data pair D- |
---|
| Lightning Protection | In compliance with: - GR-1089
- IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)
- IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)
- IEC 61000-4-5 (Lightning) L5, 95A (tp = 8/20us)
- ETSI ETS 300 386
|
|
|
Packing list