Reqiered tools
Screwdriwer set.
Pliers / pipe wrench.
Wrench set.
Additional equipment
Before mounting the equipment in an outdoor environment, please make sure that:
|
In case of device with external antenna, to mount and connect an external antenna to the InfiMAN Evolution/InfiLINK Evolution E5-BSE ODU and E5-STE ODU, proceed as follows:
Any external antenna of the same type and with a maximum gain not greater than those listed below can be used with the InfiMAN Evolution / InfiLINK Evolution E5-BSE in the countries abiding by the FCC rules.
If other antenna types than above with Gain +16 dBi or LESS are used with this device these antenna types must be approved by FCC with C2PC application by device manufacturer. External antenna must be professionally installed pursuant to the section 15.203 of the FCC Rules. |
Any external antenna of the same type and with a maximum gain not greater than those listed below can be used with the InfiMAN Evolution / InfiLINK Evolution E5-STE, E6-STE in the countries abiding by the FCC rules.
If other antenna types than above with Gain +18 dBi or LESS are used with this device these antenna types must be approved by FCC with C2PC application by device manufacturer. External antenna must be professionally installed pursuant to the section 15.203 of the FCC Rules. |
In order to prevent device damage make sure that antenna is connected to both N-type connectors with serviceable RF cables before switching on. |
Connect the Cat5e FTP cable with a shielded connector covered by a cap to the "OUT" port of the power supply, having previously touched the power supply connector case with FTP cable connector case.
The power supply must not operate near a direct heat source, near water or in an environment with high humidity. The cables must be connected in such a way to prevent water flow to the power supply connectors. |
Connect the power cord to the power supply and then to the power circuit.
Use mains supply cords that adhere to safety regulations of the country where the equipment is getting deployed. |
Make sure a small loop (at least 10 cable diameters) is provided before the Cat5e FTP cable enter into the building.
Please note that the pressure equalization system in Infinet devices is performed via gas exchange through a cable gland and Ethernet cable jacket with a dry room where the power supply is installed. In order to avoid ODU failure due to moisture entering the device, for example, during the pressure drop during the rain, the cable gland assembly requirements should be met and there are should be no cracks in the Ethernet cable jacket. In addition, you should avoid the Ethernet cable bending near the ODU and pinching with clamps, that can bring to the pressure equalization system fault between the internal volume of the sealed ODU and the external environment during a sudden air temperature change. This may lead to the leakage and device failures. |