AUX-ODU-LPU-G Mounting

 AUX-ODU-LPU-G can be installed on a pole, using hose clamps. Attach the grounding cable (min cross-section 2.5 mm2) to the case, using grounding bolt.

Center

Gliffy Diagram
nameAux-odu-lpu on pole R5000

During AUX-ODU-LPU-G mounting it is necessary to provide a small loop of the FTP Cat5e cable that should be below the cable gland. These ensure that water is not constantly channeled towards the connectors. It will also serve as a cable compensator for the cable linear expansion as the temperature difference result.

Center

Gliffy Diagram
nameAux-odu-lpu-g_loop R5000

Warning
titleCAUTION

Missing or bad grounding may leave the unit vulnerable to lightning damage.

AUX-ODU-LPU-G Cable Ggland Assembly

In order to ensure that the cable gland remains sealed under any environmental conditions, please, follow the assembly sequence according to the procedure below:

  • Step 1: Insert the sealing insert into the clamping claw.
  • Step 2: Assemble the cable gland by putting the thread-lock sealing nut, clamping claw with sealing insert and body onto the cable as shown on the figure.
  • Step 3: Insert the clamping claw with sealing insert into the body as shown on the figure.
  • Step 4: Crimp the standard RJ-45 connector onto the cable using crimping tool. Pin-out scheme: T568B wiring standards.
Warning
titleCAUTION

Make sure that the RJ-45 connector is well-crimped. A loose connector can damage the device. Please note that such damage is not covered by the warranty. 

Note
titleNOTE

For connection to "ETH IN" terminate the cable with the standard RJ-45 connector (4) according to the EIA/TIA-568B.

For connection to "ETH OUT" terminate the cable with the shielded RJ45 connector (5)  according to the EIA/TIA-568B (to provide grounding circuit).

Center

Gliffy Diagram
nameaux-odu-lpu_scheme connection R5000

  • Step 5: Insert the Rj-45 connector into the corresponding socket until you hear a click.
  • Step 6: Screw the cable gland body into the port and tighten it. Do not apply excessive force.
  • Step 7: Tighten the thread-lock sealing nut. Do not apply excessive force.
Center

Gliffy Diagram
nameAUX-ODU-LPU cable assembling R5000