Page tree

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Include Page
_IW Academy
_IW Academy

Hide_comments

  1. Unpack the equipment.
  2. Check items integrity.
  3. Determine the FTP cable length that is used to connect IDU and ODU. The total cable length between LAN (behind IDU) and ODU should not be longer than 100 meters.

    Center
    Scroll Title
    titleFigure - Connection scheme

  4. Install (solder) connector for ODU on the FTP cable and isolate it.
  5. Lay the FTP cable “from top to bottom” – from ODU to IDU.
  6. After the FTP cable has been laid, use distribution box to switch from FTP cable to UTP cable with RJ-45 connectors. Service cable connecting IDU and ODU should be FTP Cat5e cable with the outside diameter value not more than 7mm.
  7. Install ODU on the mounting bracket according to the direction required for the link. Do not tight it too hard unless the antenna alignment is not complete. Install ODU connectors down.
  8. Connect the ODU-IDU cable to the ODU.
  9. Isolate the ODU connector joint place.
  10. Once the ODU and antenna pole are installed they must be grounded via lightning protection grounding contour. ODU position must be lower than the highest antenna pole point at least by 2 ODU heights.

    Center
    Scroll Title
    titleFigure - Installation scheme

  11. Connect the FTP cable to IDU. 

    Warning
    titleCAUTION

    The power supply must not operate near a direct heat source, near water or in an environment with high humidity. The cables must be connected in such a way to prevent water flow to the power supply connectors.

  12. Provide grounding for IDU.
  13. Connect Ethernet cable to IDU.
  14. Provide power supply for IDU.
  15. Connect to the device using Telnet protocol.

...