Page tree

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Note
titleNOTE

During the configuration of the devices in a lab, take into account the following requirements:

  • Make sure that the devices are not directed at each other in order to prevent the damage of the radio modules. It is possible recommended to place the devices at a distance from each other, with the antennas directed to the floor.
  • The minimum transmit output power must be set on the devices.
  • In case of using two R5000-Omx or R5000-Lmn devices, it is recommended to connect them directly using RF cables and RF attenuators with an attenuation of at least 40 dB for each polarization (the installation\deinstallation of the RF attenuators and of the RF cables should only be performed when the devices are switched off).
  • The failure or damage of the device's radio module in case of disregarding these requirements is not covered by warranty.

...

If the device does not have a radio interface, the reason for such behavior can be the recovery mode present during the reset of the device using the ERConsole. Complete the recovery process by returning the device to the factory settings in from the Maintenance section.

Checking the firmware version

...

In the "Maintenance" section, make sure that the same software version is installed on both devices: MINT or TDMA. Instructions for switching between the MINT and TDMA software versions are available in the article "How to upgrade your network from MINT to TDMA". We recommend to update the devices to the latest beta software version.

...

To upload the software via the command line, use the "flashnet" command described in the "General Purpose Command Set" article.

Checking

...

the installation requirements

Checking the network infrastructure

If the link is not established after the installation on site, make sure that the devices were not damaged during shipping, check the integrity of the network infrastructure, the cables and the power supplies.

Checking the installation requirements

Check if the suspension height, azimuth and elevation of the antenna match with the values obtained from InfiPLANNER. Make sure that the obstacles on the path profile are not higher than those specified during the planning phase.

...