The following parameters are available in order to operate the Spectrum Analyzer:

Center
Scroll Title
titleTable - Spectrum Analyzer
ParameterDescription

Interface

  • rf5.0 radio interface is the only option available, but it is showed for the backward compatibility with the dual radio legacy products

Start Frequency

  • Set the first frequency for scanning (in MHz)

Stop Frequency

  • Set the last frequency for scanning (in MHz)

Band

  • Set the bandwidth (in MHz)

Step

  • Set the scanning frequency step (in MHz)
  • It is recommended to set 1 MHz “step” value to get more precise scanning results

Channel Mask

  • Select which antenna to be used for scanning the radio environment
  • Auto” parameter is set by default. For R5000-Omx/Mmx models with 2 radio modules it means scanning In this case scanning is perfomed by both antennasParameter
  • "31" is applicable only to R5000-Omx/Mmx models with 2 radio modules and means scanning - scanning is perfomed by antenna "1"
  • "2" - scanning is perfomed by antenna "2"
  • Parameter "3" means scanning is perfomed by both antennas

Scan Duration

  • Set the time period for the scanning process (in seconds)
  • After the end of this time period, scanning is stopped and the radio interface will be back to its normal mode operation

Enable Grid

  • Mark/unmark the corresponding checkbox to display/hide the grid lines and highlight the special frequency channel on the scan output
  • The highlighted frequency channel can be used to mark the channel which the device is currently working on or which it plans to use

Grid Width

  • Set the bandwidth value for the highlighted frequency channel (in MHz)

Grid Frequency

  • Set the central operating frequency for the highlighted frequency channel

RSSI mode

  • Select the gradient-color type for the “Max RSSI” values to be displayed on the Spectrum Analyzer output screen
  • The options are:
    • Normal (by default)
    • Gradient
    • Max Hold
    • Peak Hold

Start/stop Spectrum Analyzer by clicking the «Start Sensor Test»/«Stop Sensor Test» buttons.

By clicking the «Last Snapshot» button, you get the final scanning results. The most common usage of this feature is when you perform a spectrum scan at the remote unit on the other side of the radio link. When running a spectrum scan at such a unit (accessible via the RF interface), connection to this unit will be lost for a scan time. "Last Snapshot" option allows viewing scan results when the connection gets up again.

When you run spectrum scan on a local unit and the link is interrupted, the remote unit will not disappear from the spectrum picture. So you should silence the remote unit in order to have a real picture without it, otherwise you will always see noise signal on the operating frequency generated by the remote unit.

You can get detailed information about the scanned radio signals on a specific frequency. Just point a cursor on the needed frequency and you will see a hint with exact Signal level (dBm), Frequency (MHz), Noise Floor (dBm), RSSI (dBm), High RSSI (dBm), Max RSSI (dBm) values.