AUX-ODU-LPU-G Mounting
AUX-ODU-LPU-G can be installed on a pole, using hose clamps. Attach the grounding cable (min cross-section 2.5 mm2) to the case, using grounding bolt.
Center |
---|
Gliffy Diagram |
---|
| |
---|
name | Aux-odu-lpu on pole R5000 |
---|
|
|
During AUX-ODU-LPU-G mounting it is necessary to provide a small loop of the FTP Cat5e cable that should be below the cable gland. These ensure that water is not constantly channeled towards the connectors. It will also serve as a cable compensator for the cable linear expansion as the temperature difference result.
Center |
---|
Gliffy Diagram |
---|
| |
---|
name | Aux-odu-lpu-g_loop R5000 |
---|
|
|
Warning |
---|
|
Missing or bad grounding may leave the unit vulnerable to lightning damage. |
AUX-ODU-LPU-G Cable Ggland Assembly
In order to ensure that the cable gland remains sealed under any environmental conditions, please, follow the assembly sequence according to the procedure below:
- Step 1: Insert the sealing insert into the clamping claw.
- Step 2: Assemble the cable gland by putting the thread-lock sealing nut, clamping claw with sealing insert and body onto the cable as shown on the figure.
- Step 3: Insert the clamping claw with sealing insert into the body as shown on the figure.
- Step 4: Crimp the standard RJ-45 connector onto the cable using crimping tool. Pin-out scheme: T568B wiring standards.
Warning |
---|
|
Make sure that the RJ-45 connector is well-crimped. A loose connector can damage the device. Please note that such damage is not covered by the warranty. |
Note |
---|
|
For connection to "ETH IN" terminate the cable with the standard RJ-45 connector (4) according to the EIA/TIA-568B. For connection to "ETH OUT" terminate the cable with the shielded RJ45 connector (5) according to the EIA/TIA-568B (to provide grounding circuit). Center |
---|
Gliffy Diagram |
---|
| |
---|
name | aux-odu-lpu_scheme connection R5000 |
---|
|
|
|
- Step 5: Insert the Rj-45 connector into the corresponding socket until you hear a click.
- Step 6: Screw the cable gland body into the port and tighten it. Do not apply excessive force.
- Step 7: Tighten the thread-lock sealing nut. Do not apply excessive force.