- It is recommended to have two teams prepared for alignment procedure, each team with at least two installers: one should take the signal readings and communicate with the remote side, the other should make the adjustments with the device.
- Rough alignment is necessary as the main lobe of the device is narrow. Use the azimuth, elevation angle and suspension height from InfiPLANNER report for this process.
- There are two ways to determine the received signal level: RSSI LED on the device case or built-in graphical antenna alignment tool.
Note |
---|
To perform a correct alignment via RSSI LED display, the automatic transmit power control mechanism (ATPC) must be disabled. |
- For alignment use adjustment knobs of the MONT-KIT-85PW. After that tighten nuts M8.
...