Page tree

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Warning
titleCAUTION

The device coordinates are transmitted via the standard NMEA sequences in ASCII code. The false definition of control characters to enter to the boot monitor service mode can occur during synchronization signal receiving since the synchronization unit is connected to the console port of the base station on a non-standard rate.

In order to avoid this, before the first synchronization unit connection to in case the device with MINT it is necessary to perform the following:

1) MINT firmware:

  • Upgrade the device boot monitor via command
Code Block
languagejava
themeDJango
_upgrade -q
Note
titleNOTE

"_upgrade -q" command is available starting with firmware version "MINTv1.90.17". It is recommended to install the firmware version not lower than "MINTv1.90.25" before the boot monitor upgrade. The command can be executed via a web interface in the section "Command Line".

  • Connect the synchronization unit to the base station device console port.
  • Install Upgrade to TDMA firmware version.
  • Reboot the device
In case of synchronization unit connection to the device with TDMA firmware it is necessary to reboot
  • .

2) TDMA firmware:

  • Make sure you have the latest firmware version and then connect the synchronization unit.
  • Otherwise, update the firmware to the latest version and after reboot connect the synchronization unit.

3) Just upgraded from MINT to TDMA firmware:

  • Reboot the device and only after that connect the synchronization unit to the
base station
  • device console port.

In the section "Device Status" -> "Link Statistics" the information about synchronization status and the number of visible satellites is displayed.

...