Cable gland assembly for R5000-Mmx/Mmxb/Omx/Omxb models.

Required components:

  1. Shielded Unshielded RJ-45 connectorsconnector
  2. Connector cover
  3. Shielded RJ-45 connector
  4. FTP Cat5e cable;
  5. Cable sealing nut
  6. Cable sealing grommet
  7. Cable gland case
  8. Cable gland nut

Step 1


  • Insert the sealing grommet (6) into the cable gland case (7) as shown on the picture

Step 2


Image Added


  • Assemble the cable gland as shown on the picture by placing the cable gland nut (8) on the cable gland case (7)
  • Put the cable sealing nut (5) and the cable gland assembly (7,8) onto the cable as shown on the picture

  • Crimp the shielded unshielded RJ-45 connector (1) onto the cable using the crimping tool

Pin-out scheme: T568B wiring standards

Note
titleNOTE

The outside diameter value of the FTP Cat5e cable should not exceed 7 mm.

Note
titleNOTE

Do not use the shielded RJ-45 connector on this end of the cable as it should be attached on the IDU end.

Warning
titleCAUTION

MAKE SURE THAT THE RJ-45 CONNECTOR IS WELL-CRIMPED. A LOOSE CONNECTOR CAN DAMAGE THE DEVICE. PLEASE NOTE THAT SUCH DAMAGE IS NOT COVERED BY THE WARRANTY.

Step 3


  • Insert the cable gland assembly to the device socket

Step 4


  • Tighten the cable gland nut (8) until you hear a click by rotating it clockwise
  • Tighten the cable sealing nut (5). Do not apply excessive force

Cable gland assembly for R5000-Smn/Lmn/Smnc models

Required components:

  1. FTP Cat5e cable
  2. Shielded RJ-45 connector
  3. Unshielded RJ-45 connectorsconnector
  4. Cable sealing nut
  5. Cable gland case

Step 1


Image Added

  • Put the cable sealing nut (4) and the cable gland case (5) onto the cable as shown on the picture
  • Crimp the unshielded RJ-45 connector (3) onto the cable using the crimping tool
Note
titleNOTE

The outside diameter value of the FTP Cat5e cable should not exceed 7 mm.

Note
titleNOTE

 Do not use the shielded RJ-45 connector (2) on this end of the cable as it should be attached on the IDU end.

Warning
titleCAUTION

 Make sure that the RJ-45 connector is well-crimped. A loose connector can damage the device. Please note that such damage is not covered by the warranty.

Step 1

Image Removed

  • Put the cable sealing nut (4) and the cable gland case (5) onto the cable
  • Crimp the shielded RJ-45 connector (3) onto the cable using the crimping tool

    2


    Image Added

    • Insert the connector into the socket until you hear a click
    • Screw the cable gland case into the port and tighten it. Do not apply excessive force.

    Step 3


    • Tighten the sealing nut (4). Do not apply excessive force.

    Console cable connector soldering scheme

    Center
    Scroll Title
    titleFigure - Console cable connector soldering scheme

    Note
    titleNOTE

     A properly assembled cable gland seales against humidity.