Page tree

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Note
titleNOTE

A minimum set of requirements must be met during devices pre-configuration in the lab:

  • Make sure the devices are not directed at each other in order to prevent radio modules damage.
  • A minimum transmit output power must be set.
  • In case of two devices with external antennas, it is recommended to connect them in the link directly, with RF cables and RF attenuators with attenuation of at least 40 dB for each polarization (installation\deinstallation of the RF attenuators and RF cables should only be performed when the devices are switched off).
  • Grids shoud be the same on both Master and Slave units.

Step 1: Connection scheme 

...

  1. Connect Gigabit Ethernet port at the ODU to the power supply port labeled as "OUT".
  2. Connect Ethernet port at the laptop to the power supply port labeled as "IN".
  3. Connect the power cord to power supply and plug it to AC mains.

...

Gliffy Diagram
displayNamePreconfig in lab1 Copy
namePreconfig in lab1 Copy
pagePin

...

5

Step 2:  Access Access to the device

Let's access each unit to the default IP address 10.10.10.1 with mask 255.255.255.0 via a web browser. Before, make sure the Ethernet port of the Laptop has an IP address assigned from the same subnetwork as the one for the unit (e.g., set 10.10.10.10 with mask 255.255.255.0).

...

  • Download latest release from the ftp server ftphttps://ftp.infinet.ru/pub/Firmware.
  • In the "Maintenance" section click the "Select file" button and set the path to the downloaded file, or drug it to the specified area.
  • File will be uploaded to the device. Changes will take force after reboot.

...

Image Modified

Step 4: Radio parameters configuration

...

The rest of parameters remain with the default values.

...

Image Modified

Step 5: Check the wireless link status

Let's apply all settings described above for each unit and go to the "Dashboard" section and check if the device status has changed to "Connected".

...

Image Added