Usually, before going into the field, it is recommended to pre-configure in the lab the InfiNet Wireless units to verify the link establishment. Therefore, let's take the units to be used for this course out of the package and place them on the table.

Note
titleNOTE

A minimum set of requirements must be met during devices pre-configuration in the lab:

  • Make sure the devices are not directed at each other in order to prevent radio modules damage.
  • A minimum transmit output power must be set.
  • In case of two devices with external antennas, it is recommended to connect them in the link directly, with RF cables and RF attenuators with attenuation of at least 40 dB for each polarization (installation\deinstallation of the RF attenuators and RF cables should only be performed when the devices are switched off).

...

Let's access each unit to the default IP address 10.10.10.1 with mask 255.255.255.0 via a web browser. Before, make sure the Ethernet port of the Laptop has an IP address assigned from the same subnetwork as the one for the unit (e.g., set 10.10.10.10 with mask 255.255.255.0).

Note
titleNOTE

We assume that each unit used in this setup has not been configured before and runs with the factory settings.

...

  • Device Name (e.g., Master/Slave).
  • Login (e.g., admin).
  • Password (e.g., admin).
Center

Note
titleNOTE

At the next login, type "admin" for the Login and Password (if these are the credentials set before) to access the unit in the privileged mode.

...