- Device Name (e.g., Master/Slave).
Go to the "Settings" → "Security" section and configure:
- Login (e.g., admin).
- Password (e.g., admin).
Center |
---|
Note | ||
---|---|---|
| ||
At the next login, type "admin" for the Login and Password (if these are the credentials set before) to access the unit in the privileged mode. |
...
- Unit role: Master.
- Downlink center frequency: 5200 MHz (use values selected at the Link Planning stage).
- Uplink center frequency: 5200 MHz.
- Power limit: -5 dBm (set the minimum value in the range, as currently, we are in the lab, and we don't need high output power anymore).
- Channel width: 20 MHz (use value selected at the Link Planning stage).
- Frame length: 5 ms.
- Guard interval: 1/8.
...
- Unit role: Slave.
- Downlink center frequency: 5200 MHz (use value selected at the Link Planning stage).
- Power limit: -5 dBm (set the minimum value in the range, as currently, we are in the lab, and we don't need high output power anymore).
- Channel width: 20 MHz (use value selected at the Link Planning stage).
- Frame length: 5 ms.
- Guard interval: 1/8.
...