Page tree
Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 10 Next »

Figure - AUX-ODU-SYNC

AUX-ODU-SYNC is a TDD synchronization hub, which has been designed to provide a timing reference to the InfiNet Wireless R5000 units. In combination with InfiNet’s new proprietary TDMA-based wireless architecture, AUX-ODU-SYNC completes the solution, providing TDD synchronization to its systems, both legacy and newly deployed.

TDD synchronization eliminates self-interference between multiple co-located units and enables frequency re-use within the same site. InfiNet’s implementation supports not only intra-, but inter-site synchronization too, thanks to the fact that the timing reference is GNSS-based.

ParameterDescription
Compatible models
  • InfiMAN 2x2 family: Mmxb(s), Omxb(s), Qmxb
  • InfiLINK 2x2 PRO family: Mmx(s), Omx(s)
GNSS receiver
  • Embedded, GPS/GLONASS
GNSS antenna
  • Embedded, active
Water and Dust protection
  • IP66 and IP67
Consumption, W
  • up to 4
Input voltage, VDC
  • ±19..±56
PoE type
  • Passive PoE (4,5,7,8 Ethernet pins used)
Interfaces and connectors
  • Port 0-6: sync outs (7 RJ-45 connectors to connect to ODU with special cable CAB-SYNC)
  • Power: power supply input (1 RJ-45 connector)
Compatible InfiNet Wireless power supplies
Size and Weight
  • 180х170х75mm, 0.65kg
Table - AUX-ODU-SYNC specification

The set of indicators is located near the power port of AUX-ODU-SYNC:

DescriptionNormal state
Power (POWER)On 
TDD-synchronization (SYNC)On
Table - AUX-ODU-SYNC indicator panel description