High-precision MONT-KIT-85PW is supplied with device by default. It allows to make reliable and easy installation of the unit with two-axis adjustment. 

Packing List

MONT-KIT-85PW_packing list

Assemble Procedure

Step 1: Tighten the Assemble kit and Bracer to the pole using bolt M8, washer flat M8 and washer spring M8.

  • Bolt M8x50 - used for installation on pole with Ø 30 ... Ø 55 mm.
  • Bolt M8x80 - used for installation on pole with Ø 55 ... Ø 85 mm.

Step 2: Attach the ODU and Assemble kit using bolts M5x10, M5x16, washer flat M5 and washer spring M5.

NOTE

Assemble kit is already adjust. In case you require additional adjustment, perform weaken on 1/8 turn using handles. After alignment tighten screws M5x10 and M5x16.

MONT-KIT-85PW

Mounting is carried out on a pole with a diameter 30-85 mm. There are also possible options for mounting on a wall or pole with a diameter more than 85 mm.

Pole mount_Q70
Установка

NOTE

Optional fasteners are not included in the Mounting kit MONT-KIT-85PW.