Figure - IDU-CPE-DC top view

IDU-CPE-DC is an indoor DC/DC injector. It greatly reduces complexity of the deployment in the cases where DC source is available thus reducing both capital expenditures and total cost of ownership. It is desinged for all CPE units (Smn and Lmn) and has integrated lightning protection. The source of DC power supply can be +48 V or even -48 V, hence installation of CPE units is possible where other DC or AC power sources are unavailable.

ParameterDescription
Compatible modelsInfiLINK 2x2 and InfiMAN 2x2 series CPE ODU (Smn and Lmn)
Connectors and Interfaces
  • "Switch HUB" - Ethernet input (Data only)
  • "RJ45" - Ethernet output (Data+VDC), protected leg
  • "VIN+" - DC+ Input
  • "VIN–" - DC– Input
  • "FG" - ground clamp
Supported Ethernet Modes
  • 10/100 Mbps (Fast Ethernet pass-through)
Input voltage
  • ±36 ... 72 V
Output voltage
  • +48 V, 0.5 A
Power consumption
  • 24 W
Ethernet Connectors Pinout
  • "Switch HUB": 4, 5, 7, 8 - not connected
  • "RJ45": 4, 5 (+VDC) and 7, 8 (-VDC)
Lightning
  • IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)
  • IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)
  • IEC 61000-4-5 (Lightning), 20A (tp = 8/20us)
EMCFCC Class B , EN55022 Class B, EN60945, EN50155
SafetyUL1950, CSA 22.2 & TUV EN60950
Size and Weight85x57x36 mm, 0.15 kg