Q70-50 model installation is performed using mounting kit that is supplied by default. Install the device according to the scheme below.

Q70-50 Mounting

Assemble Procedure

Step 1: Put Bolts M8x165 to its sockets, attach to the mast and assemble Bracers on the bolts. Put the Nuts M8 and Washers (flat and spring) on the bolt without fastening.

Step 2: Roughly aim the mounting kit with the sight view line towards the target.

Step 3: Use tightening torque of 16 Nm on the Nuts of Bolts M8x165 with 12.7 open end, or deep socket wrench. Tool's length should not exceed 20 cm.

Step 4: Use initial tightening torque of 10 Nm on Central bolts and Bolts M8x50. Use 12.7 open end, or deep socket wrench.

Step 5: Screw the Elevation adjustment bolt to its position shown in the scheme#1 below.

NOTE

After installation, the devise should go through periodical inspection at least once a year and maintenance to verify proper condition of the antenna system by qualified personnel. Infinet will not be liable to any failure, damage, safety or other problem results due to a failure to follow these instructions, misuse or improper handling.



  • No labels