InfiMONITOR polles devices via the SNMP protocol. Therefore each device in the network should have SNMP agent running and configured to perform the devices management and monitoring.
...
Code Block |
---|
|
snmpd user USERNAME add pass PASSWORD security authNoPriv accessRights
readWrite class admin |
Note |
---|
|
Only protected mode "authNoPriv" is supported by InfiMONITOR |
...
Code Block |
---|
|
mint rf5.0 rcmd -node all -self -cmd "snmpd user USERNAME add pass PASSWORD
security authNoPriv accessRights readWrite class admin"
mint rf5.0 rcmd -node all -self -cmd "snmpd start"
mint rf5.0 rcmd -node all -self -cmd "config save" |
In order to enable "SNMP Trap" simultaneously for all CPE s connected to the BS (including BS too), on the BS execute the following commands (replace "IP ADDRESS" with the InfiMONITOR IP-address)
Code Block |
---|
|
mint rf5.0 rcmd -node all -self -cmd "trapd start"
mint rf5.0 rcmd -node all -self -cmd "trapd dst IP ADDRESS:162/v2"
mint rf5.0 rcmd -node all -self -cmd "trapd type topoGroup enable"
mint rf5.0 rcmd -node all -self -cmd "trapd type radioGroup enable"
mint rf5.0 rcmd -node all -self -cmd "trapd type mintGroup enable"
mint rf5.0 rcmd -node all -self -cmd "trapd type ospfGroup enable"
mint rf5.0 rcmd -node all -self -cmd "trapd type linkEvent enable"
mint rf5.0 rcmd -node all -self -cmd "trapd typetrapdColdStartEvent enable"
mint rf5.0 rcmd -node all -self -cmd "trapd type snmpdAuthenticationFailureEvent enable"
mint rf5.0 rcmd -node all -self -cmd "trapd type syslog enable"
mint rf5.0 rcmd -node all -self -cmd "config save" |
Configure the agent IP-address separately, for each device (replace"IP ADDRESS" with the device IP-address value)
...