Page tree

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Hide_comments

Center
Scroll Title
titleFigure - IDU-LA-G(V.01) top view

Image Removed

IDU-LA-G(V.01) is an indoor DC/DC injector. It greatly reduces complexity of the deployment in the cases where DC source is available thus reducing both capital expenditures and total cost of ownership.

...

  • To serve as a line protection unit for indoor network equipment connected to the second Ethernet port on ODU.
  • To connect third-party DC power sources to ODU (for example, to power the unit from solar power or wind power sources).

In both cases IDU-LA-G(V.01) should be properly grounded (please refer to the “Grounding and Lightning Protection” section of this manual).Technical parameters

Center
scroll-title
Parameter
titleFigure - IDU-LA-G front panel view

Image Removed

Center
Scroll Title
titleFigure - IDU-LA-G(V.01) inside view

Image Removed

Size 115×65×40 mm (L×W×H), weight 0.15kg

Center
Scroll Title
titleFigure - Mounting holes sizes

 Image Removed

Input voltage supported for InfiNet Wireless models and devices.

Center
Scroll Title
titleTable - Input voltage
Input voltage, VDCModel

+9…+56

R5000-SmnR5000-LmnR5000-SmnbR5000-SmncR5000-Lmnc
±43…±56R5000-MmxR5000-OmxR5000-MmxbR5000-OmxbR5000-QmxbUmXmAUX-ODU-SYNC
Description
Compatible modelsInfiLINK XG, InfiLINK XG 1000, InfiLINK 2x2, InfiMAN 2x2, Quanta 5, Quanta 6, Quanta 70, InfiLINK Evolution, InfiMAN Evolution
Output VoltageThe same as input
Supported Ethernet Modes10/100/1000 Mbps (Gigabit Ethernet pass-through)
Pin assignment and polarity1/2 (+), 3/6 (-), 4/5 (+), 7/8 (-)
DC RangeAcceptable input DC range depends on the specific ODU model:
InfiLINK XG, InfiLINK XG 1000, InfiLINK 2x2 PRO, InfiMAN 2x2 BS, Quanta 70, Quanta 5, Quanta 6, InfiLINK Evolution, InfiMAN Evolution models: ±43... ±56 VDC
InfiLINK 2x2 Lite, InfiMAN 2x2 STE models: +9... +56 VDC (positive voltage only)
Size and Weight115×65×40 mm, 0.15 kg
Operating temperature rangefrom 0°С to +40°С
Warning
titleCAUTION

Exposing unit to the unsupported voltage will result in irreparable damage to the unit! Always observe power requirements!

Connectors description

Gliffy Diagram
nameIDU-LA-G(V.01)

...

_eng
pagePin1

Mounting holes sizes

Gliffy Diagram
size550
nameIDU-LA-G(V.01)_mounting holes
pagePin1

IDU-LA-G(V.01) Packing List

...

Gliffy Diagram

...

nameIDU-LA-G(V.01)

...

Image Removed

...

  • Connector and cable assembly
    • Connector: DC plug, on cable, 2,1х5,5х9 mm
    • Сable length: 1,5 ... 1,6 m

...

Image Removed

...

  • Standard RJ-45 (2 pcs)

...

Image Removed

...

_Packing list
pagePin1

Cable assembly

Gliffy Diagram
nameCable Inf-cable-001
pagePin1