The maximum throughput of a single port is limited to the standard 100Base-TX. The throughput of the radio module depending on the MCS and the channel width can be higher. R5000 devices Devices of Lite seriesInfiMAN 2x2 and InfiLINK 2x2 families can achieve the maximum throughput up to 180 Mbps of the bi-directional aggregated stream. It is not possible to use the maximum throughput of the radio channel in one direction through one 100Base-TX port. However, the combination of ports into one LAG allows achieving the maximum throughput in one direction.

...

Configuration via GUI
Anchor
GUILAG
GUILAG

  1. Create LAG interface.
  2. Add ports.
  3. Choose LACP (Standard or Fast mode). "Standard" LACP fully complies with the standard IEEE 802.3ad. “Fast” LACP uses only with Infinet devices and increases efficiency and performance compared default compared "Standart" mode.

    Warning
    titleAttention

    The "Fast" mode is a proprietary extension of the LACP protocol. Compatibility of this mode is guaranteed only with devices that support the MINT protocol.


  4. Configure management IP for LAG interface or SVI (optionally).
  5. Configure switch group.

Configuration via CLI

Code Block
languagetext
themeEmacs
titleConfiguration of LAG in WANFlex
lag N [command] [(port|-port) (IFNAME | IFNAME...)]

...