Page tree
Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 18 Current »

Figure - AUX-ODU-INJ-G

Optional indoor/outdoor DC injector with built-in lightning protection. It greatly reduces complexity of the deployment in the cases where DC source is available on the rooftop eliminating the need of weather-sealed cabinets. AUX-ODU-INJ-G is compatible with all Infinet Wireless devices.

ParameterDescription
Size and Weight34x94x121 mm, 0.28 kg
Connectors and Interfaces
  • ETH IN - Ethernet input
  • ETH OUT - Ethernet output (data+VDC, protected leg)
  • PWR - DC Input
  • GND - Ground clamp
Supported Ethernet Modes
  • 10/100/1000 Mbps (Gigabit Ethernet pass-through)
Water and Dust Protection
  • IP66 and IP67
Operating temperature range
  • -55 °C ... +60 ºC
DC Range
  • InfiLINK XG, InfiLINK XG 1000, InfiLINK 2x2 PRO, InfiMAN 2x2 BS, Quanta 70, Quanta 5, Quanta 6, InfiLINK Evolution, InfiMAN Evolution: ±43...±56 VDC 
  • InfiLINK 2x2 Lite, InfiMAN 2x2 STE: +9... +56 VDC (positive voltage only)

CAUTION

Using inappropriate DC source will damage the ODU, which will be not covered by warranty

Ethernet Connectors Pin-outETH INPin12345678
DescriptionData pair A+Data pair A-Data pair B+Data pair C-Data pair C+Data pair B-Data pair D+Data pair D-
ETH OUTPin12345678
DescriptionData pair A+Data pair A-Data pair B++VDC + Data pair C-+VDC + Data pair C+Data pair B--VDC + Data pair D+-VDC + Data pair D-
Lightning Protection

In compliance with:

  • GR-1089
  • IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)
  • IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)
  • IEC 61000-4-5 (Lightning) L5, 95A (tp = 8/20us)
  • ETSI ETS 300 386
Table - AUX-ODU-INJ-G Specifications

Packing List

AUX-ODU-INJ Packing List

AUX-ODU-INJ-G is supplied with a worm clamp TORRO 40-60/9 C7 W4 DIN 3017 - 2 pcs. The clamp is made of stainless steel A4, width 9 mm, allows the installation on a mast with a diameter of 35 to 60 mm. In case of mast diameter more than 60 mm, a similar clamp (up to a 230 mm diameter) with a width of up to 12-13 mm can be used.