Figure - IDU-LA-G(V.01) top view

IDU-LA-G(V.01) is an indoor DC/DC injector. It greatly reduces complexity of the deployment in the cases where DC source is available thus reducing both capital expenditures and total cost of ownership.

IDU-LA-G(V.01) may be used for the following purposes:

  • To serve as a line protection unit for indoor network equipment connected to the second Ethernet port on ODU
  • To connect third-party DC power sources to ODU (for example, to power the unit from solar power or wind power sources).

In both cases IDU-LA-G(V.01) should be properly grounded (please refer to the “Grounding and Lightning Protection” section of this manual).

Figure - IDU-LA-G front panel view

Figure - IDU-LA-G(V.01) inside view

Size 115×65×40 mm (L×W×H)

 

Figure - Mounting holes sizes

Input voltage supported for InfiNet Wireless models and devices.

ModelInput voltage, VDC

R5000-Smn

R5000-Lmn

AUX-ODU-SYNC

+9…+56

R5000-Mmx

R5000-Omx

R5000-Qmxb

InfiLINK XG

±43…±56

Table - Input voltage

CAUTION

Exposing unit to the unsupported voltage will result in irreparable damage to the unit! Always observe power requirements!

IDU-LA-G(V.01) Packing List

ComponentDescription

  • IDU-LA-G(V.01)

  • Connector and cable assembly

  • Standard RJ-45 (2 pcs)

  • Shielded RJ-45 (1 pcs)
Table - IDU-LA-G(V.01) Packing List