Page tree
Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

For this example, we have two InfiNet Wireless R5000 units with the default factory configuration.

  • Step 1

In order to access each of the units, we have to make sure that there is network connectivity between the PC used for the configurations and the units on their default Ethernet IP address which is 10.10.20.1/24.

  • Step 2

Connect to the first unit using a Web browser and type any username and any password in the corresponding fields. Let’s use in this example “test” for both username and password. After the authentication, a warning message pops up and requests us to change these initial authentication credentials:

Figure - Warning message – setup system login & password
  • Step 3

In order to change the initial credentials, we have to go to "Basic Settings" → "System Settings" and fill in the “User Name” and “Password” fields with the permanent authentication credentials. Let’s use in this example “Node1” user name and “Infi1” password for the first unit and “Node2” user name and “Infi2” password for the second unit.

In the same section, we set the “Device Name” parameter for each unit. Let’s name in this example “Node1” the first unit and “Node2” the second unit:

Figure - Edit system settings
  • Step 4

In "Basic Settings" → "Network Settings" section, we can change the default IP address of the svi1 interface. Let’s add the IP 192.168.1.1/24 for the first unit and the IP 192.168.1.2/24 for the second unit:

Figure - Add IP address on svi1 interface
  • Step 5

In order to establish a wireless link between the two units, we have to set one of them as Master. By default, both units are configured as Slave.

In "Basic Settings" → "Link Settings" section let’s configure the following radio parameters for the first unit:

  • Type: Master
  • Polling: On
  • DFS: Off
  • Node ID: 1
  • Channel width: 40 MHz
  • Frequency: 5870 MHz

Figure - Set the radio parameters for the Master unit
  • Step 6

Now we can save all settings performed in "Basic Settings" menu by clicking the «Apply» button at the bottom of the page.

  • Step 7

We have now to connect to the second unit to its default IP address and to perform the configuration below:

  • In "System Settings" section
    • Device Name: Node2
    • User Name: Node2
    • Password: Infi2
  • In "Network Settings" section
    • svi1 IP address: 192.168.1.2/24

  • In "Link Settings" section

    • Type: Slave
    • Node ID: 2
    • Channel width: 40 MHz
    • Frequency: 5870 MHz

We have to save all settings performed in "Basic Settings" menu by clicking the «Apply» button at the bottom of the page.

  • Step 8

We connect now back to the first unit at the IP 192.168.1.1/24, and go to "Device Status" menu in order to check the link establishment between our two units and all real-time parameters provided by Web interface:

Figure - Wireless link establisment
  • No labels