IDU-LA-G(V.01) is an indoor DC/DC injector. It greatly reduces complexity of the deployment in the cases where DC source is available thus reducing both capital expenditures and total cost of ownership.
IDU-LA-G(V.01) may be used for the following purposes:
- To serve as a line protection unit for indoor network equipment connected to the second Ethernet port on ODU.
- To connect third-party DC power sources to ODU (for example, to power the unit from solar power or wind power sources).
Technical parameters
Parameter | Description |
---|---|
Compatible models | InfiLINK XG, InfiLINK XG 1000, InfiLINK 2x2, InfiMAN 2x2, Quanta 5, Quanta 70 |
Output Voltage | The same as input |
Supported Ethernet Modes | 10/100/1000 Mbps (Gigabit Ethernet pass-through) |
Pin assignment and polarity | 1/2 (+), 3/6 (-), 4/5 (+), 7/8 (-) |
DC Range | Acceptable input DC range depends on the specific ODU model: • Xm, Um, Mmx, Mmxb, Omx, Omxb, Qmxb, Q5 , Q70 models: ±43... ±56 VDC • Smnb, Smn, Lmn models: +9... +56 VDC (positive voltage only) |
Size and Weight | 115×65×40 mm, 0.15 kg |
Operating temperature range | from 0°С to +40°С |
CAUTION
Exposing unit to the unsupported voltage will result in irreparable damage to the unit! Always observe power requirements!
Connectors description
Mounting holes sizes
IDU-LA-G(V.01) Packing List
Cable assembly