Page tree
Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

Successfully pass the free certification exam at IW Academy and become an Infinet Certified Engineer.

To the certification exam

Make sure the connectivity is provided between the control center and the device installation point. If the access is missing to the Infinet device only, further actions must be performed at the device installation site.

Indicators

Pay attention to the indication on the device enclosure.

NOTE

The LED indication on the device can be disabled administratively, make sure there is no "system no indicator" command in the last saved device configuration. We recommend to save backup configurations to the internal memory of the device and to a folder on your PC. The device can store 8 configuration backups. When saving the current configuration, its previous version is automatically added to the backup list with record number 0. All operations with device configurations are performed using the "config" command.

If the power and Ethernet indicators are off, check the integrity of the power supply, Ethernet cables, RJ-45 connectors. Replace power supply and cables with definitely working.

R5000-Mmx, R5000-Qmx and R5000-Omx

The R5000-Mmx, R5000-Qmx, and R5000-Omx have two LED indicators (red and green) located in the console port. These indicators help to monitor the device status during the installation. The correspondence between the indicators states and the current device state is shown in the table below.

Индикация H08 Copy
Figure - LED indication of R5000-Mmx, R5000-Qmx, R500-Omx devices
Red indicatorGreen indicatorDevice status
OffOffDevice is switched off of in the process of start-up booting
OffBlinkingDevice is booted. No radio connection. Searching for another device to establish radio connection to
BlinkingOnRadio connection established. The more data is transmitted through the radio channel the more frequently red indicator is blinking
Table - LEDs modes and device status of R5000-Qmxb, R5000-Mmx and R5000-Omx models

R5000-Smn and R5000-Lmn

R5000-Smn and R5000-Lmn devices have a special LED indicator set located at the back of each device, displaying the current device state.

H11 индикация Copy
Figure - LED indication of R5000-Smn, R5000-Lmn devices
IndicatorStatusDevice status
PWROnThe device is powered on
RFBlinkingRF-link is being established
OnRF-link established
ETHOnWired link established
Signal level
This scale displays current RF signal level and is designed to provide assistance in device alignment and link quality estimation. The scale is based on the SNR RX level, the threshold values for the indicator: 4, 8, 16, 30, 40 dB. The more often indicator flashes, the better quality of the connection.
Table - LED indicators modes and device status of R5000-Smn and R5000-Lmn models

Access recovery

If the power indicator is on and there is connection via the Ethernet interface, connect to the device directly as it is shown in the scheme below. Make sure the IP address of PC is in the same subnet as the device's one. You can restore the IP address and reset the device to factory settings using the ERConsole utility.

The device restoring process using the utility is described in the "Emergence Repair Console" article.

Схема ERC R5000 Copy
Figure - The recommended connection scheme

Checking the Ethernet interface status

Wired interface statistic

Web interface

If you were able to access the device by connecting directly, try to determine the possible reason for the unavailability through the network. Pay attention to the wired interface statistics. In order to do this, go to the "Device status" section of the web interface, open the "General statistics" window for the Ethernet interface in the "Interface statistics" section. Pay attention to the CRC errors number, they indicates a violation of data integrity during transmission over the wired segment. Also, the problem can be caused by a queue overflow or an inappropriate frame size (Out of range).

Figure - Interface statistics

The description of parameters for more complete diagnostics is available in the "Device status" article. 

Command line interface

If there is no access to the device web interface, run the "ifconfig eth0" command to get statistics via the CLI.

The description of parameters for more complete diagnostics is available in the "Ifconfig command (interfaces configuration)article.

Duplex mode

Pay attention to the duplex mode on the network devices connected to the wireless router. This information is available in the the web interface, proceed to the "Device status" section - "Interface statistics" and open the "General statistic" for the Ethernet interface, or by run the "ifconfig eth0" command in the command line interface.

Figure - Duplex mode

We recommend to set the auto-negotiation mode provided by the Ethernet standard. The problem can occur due to connection of two devices with different duplex settings. For example, if one device is in auto-negotiation mode, and the other in fixed full duplex mode.