  • It is recommended to have two teams prepared for alignment procedure, each team with at least two members: one should take the signal readings and communicate with the remote end, the other should manipulate the antenna.
  • For rough alignment use the azimuth, elevation angle and suspension height from InfiPLANNER report.
  • On the device case there is a RSSI value in dBm indicating the received signal level.
  • For antenna alignment use adjustment knobs of the MONT-KIT-85PW. After adjustment tighten nuts M8.
Note
titleNOTE

For further adjustment if needed weaken the nuts M8 on about 15 degrees. Perform required antenna alignment and then tighten nuts M8.

Do not adjust knobs without weaken the nuts first.

  • For more accurate alignment, use the alignment tool built into the device web interface.
  • After the initial alignment, the device at the remote side must be fixed. Firstly, the alignment is performed for one device, then for another.

...